GENERAL |
Minimum range | : 25m (when measurement range is 1⁄8 NM) |
Maximum range | : MR-1000RII 36NM MR-1000TII 48NM |
Measurement range(NM)
| : 1/8, 1/4, 1/2, 3/4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36, 48* * MR-1000TII only |
Preheat time | : 90sec. |
|
DISPLAY UNIT |
Display type | : 10″ monochrome CRT |
Resolution | : 640 × 480 dots |
Power supply requirement | : 10.2–42V DC (negative ground) |
Power consumption (approx.) | : MR-1000RII 60W (approx.) MR-1000TII 70W (approx.) |
Operatable temp. range | : –15°C to +55°C |
Unit of distance | : NM (nautical mile), km |
Dimensions (proj. not incl.) | : 269(W) × 264(H) × 258(D) mm |
Weight (approx.) | : 6.5kg |
Input data format | : NMEA 0183, N+1, AUX |
|
SCANNER UNIT |
Model Name | |
Type | : 60cm slotted waveguide array in radome | : 120cm slotted waveguide array
|
|
Rotation speed | : 24/36/48rpm typ. | : 24/36/48rpm typ. |
|
Beamwidth Horizontal beam Vertical beam | : 4° typ. 22° typ. | : 2° typ. 25° typ. |
|
Sidelobe | |
Polarization | |
Dimensions (projections not included) | : 607(Ø) × 243(H)mm | : 1205(d) × 381(H) mm |
|
Weight (approx.) | |
Operating temperature range | : –25°C to +70°C
| : –25°C to +70°C
|
|
Frequency | : 9410MHz ±30MHz | : 9410MHz ±30MHz |
|
Peak output power | |
Pulse-width/Reception rate | : 80nsec./2880Hz, 80nsec./2160Hz, 250nsec./2160Hz,350nsec./2160Hz, 900nsec./720Hz | : 80nsec./2880Hz, 80nsec./2160Hz, 250nsec./2160Hz,350nsec./2160Hz, 900nsec./720Hz |
|
Modulator | : FET switching | : FET switching |
|
Mixer and local oscillator | : Microwave integrated circuit | : Microwave integrated circuit |
|
Intermediate frequency | |
IF passband width | : 10MHz, 3MHz | : 10MHz, 3MHz |
|
Tuning | : Auto or manual | : Auto or manual |
|
System cable | : 15m (49.2ft); OPC-1188 | : 20m (65.6ft) |
|
|